Found 16 Products For "
overcurrent relays
"
Custom AC Bimental Magnetic Overcurrent Relays Current Range 0.1 - 22A 3P Standard Type
UKH-22/3 OEM /ODM acceptable Custom AC Bimental Magnetic Thermal Overload Relay Current range 0.1~22A 3P Standard type General: Bimetallic thermal overload relays use a bimetallic strip to mechanically open the contacts. Bimetallic strips consist of two conjoined pieces of metal which expand at different rates when exposed to heat. This difference forces the strip to bend when heated. In a thermal relay, the strip is attached by a spring to a contact. When excess heat from
Custom AC Bimental Magnetic Thermal Overload Contactor Relay GTH-85
Custom AC Bimental Magnetic Thermal Overload Contactor Relay GTH-85 Bimetallic thermal overload relays use a bimetallic strip to mechanically open the contacts. Bimetallic strips consist of two conjoined pieces of metal which expand at different rates when exposed to heat. This difference forces the strip to bend when heated. In a thermal relay, the strip is attached by a spring to a contact. When excess heat from overcurrent causes the strip to bend and pull the spring, the
GTH-12M Mini Motor Thermal Overload Relay , Overload Protection Relay
GTH-12M Mini Motor Thermal Overload Relay , Overload Protection Relay Thermal overload relays are protective devices. They are designed to cut power if the motor draws too much current for an extended period of time. To accomplish this, thermal overload relays contain a normally closed (NC) relay. When excessive current flows through the motor circuit, the relay opens due to increased motor temperature, relay temperature, or sensed overload current, depending on the relay
GTH40 UL Magnetic Thermal Overload Relay Electrical Protective Relays
GTH40 UL Magnetic Thermal Overload Relay Electrical Protective Relays UKH series thermal overload relays apply to circuit of AC 50Hz or 60Hz, rated voltage to below 660V and rated current . 1A-800A for AC motor overload and open-phase protection during long time or intermittent long time service, which can also protect 3-phase serious imbalance and long starting time of motor or long timer operation, can also be used for corresponding AC contactor for electromagnetic starter.
Safety Phase Failure Protection Industrial Relays , Easy Operation
Safety Phase Failure Protection Industrial Relays , Easy Operation Thermal overload relays are protective devices. They are designed to cut power if the motor draws too much current for an extended period of time. To accomplish this, thermal overload relays contain a normally closed (NC) relay. When excessive current flows through the motor circuit, the relay opens due to increased motor temperature, relay temperature, or sensed overload current, depending on the relay type.
GTH-220 Three phase Electronic Overload Relays for Motor Contactor
GTH-220 Three phase Electronic Overload Relays for Motor Contactor UKH series thermal overload relays apply to circuit of AC 50Hz or 60Hz, rated voltage to below 660V and rated current . 1A-800A for AC motor overload and open-phase protection during long time or intermittent long time service, which can also protect 3-phase serious imbalance and long starting time of motor or long timer operation, can also be used for corresponding AC contactor for electromagnetic starter.
Electromagnetic Relay Motor Protection Thermal Overload Relay UL Approvals
Electromagnetic Relay Motor Protection Thermal Overload Relay UL Approvals UKH series thermal overload relays apply to industrial circuit of AC 50Hz or 60Hz, rated voltage to below 660V and rated current . 1A-800A for AC motor overload and open-phase protection during long time or intermittent long time service, which can also protect 3-phase serious imbalance and long starting time of motor or long timer operation, can also be used for corresponding AC contactor for
Automatic Inverse Time Protective Relays IDMT Overcurrent Protection
Automatic Inverse Time Protective Relays IDMT Overcurrent Protection Time overcurrent relays operate with a time delay, which is adjustable. For given setting, the actual time delay depends on the current through the relay coil. Higher current will cause a faster operation of the relay. The minimum relay operation current (pick-up current) is also adjustable. The most commonly used overcurrent relay has both the instantaneous response for very large currents and the inverse
AC IDMT Automatic Overcurrent Protection Relay 5A Single Phase
AC IDMT Automatic Overcurrent Protection Relay 5A Single Phase A relay is intended protect loads or circuits from excessive current. Description: Purple Horn overcurrent protection delivers comprehensive protection schemes for low voltage applications. All Mikro's overcurrent units are microprocessor-based numerical relays and are housed in high-strength protective casing. The models in the range provide a wealth of options including programmable relay outputs to static, and