Send Message
Home ProductsMini Circuit Breaker

1P+N 10kA Residual Circuit Breaker 2 Pole with Over Current RCBO

1P+N 10kA Residual Circuit Breaker 2 Pole with Over Current RCBO

  • 1P+N 10kA Residual Circuit Breaker 2 Pole with Over Current RCBO
1P+N 10kA Residual Circuit Breaker 2 Pole with Over Current RCBO
Product Details:
Place of Origin: China
Brand Name: KRIPAL
Certification: CE
Model Number: UKL7
Payment & Shipping Terms:
Minimum Order Quantity: 1000 pcs
Price: negotiable
Packaging Details: 12 poles packed in one small box and then in carton
Delivery Time: 20 days and depends on ordering quantity
Payment Terms: T/T, L/C
Supply Ability: 200000 pcs per month
Contact Now
Detailed Product Description
Breaking Capacity: 10 KA Poles Available: 1P+N, 2 Pole
Ampere: 6A,10A,16A,20A,25A,32A,40A, Residual Protection: Yes
Overload Protection: Yes Type: Mini Circuit Breaker
High Light:

small circuit breaker

,

compact circuit breaker

 

1P+N 10kA Residual Circuit Breaker 2 Pole with Over Current RCBO

 

 

Description:

 

Residual circuit breaker is suitable for the leakage protection of the line of AC 50/60Hz, rated voltage single phase 240V, rated current up to 63A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will automatically cut off the power within 0.1s to protect human safety and prevent the accident due to the current leakage. leakage breaker can protect against overload and short-circuit. It can be used to protect the line from being overloaded and short-circuited as wellas infrequent changeover of the line in normal situation. It complies with standard of IEC/EN61009-1 and GB16917

 

 

Main features:

 

1. Action function independent of the voltage of main circuit

 

2. The neutral line breaking could make the device after and more reliable

 

3. Dual-function wiring terminal with strong wiring capability

 

4. The indicator for contact state help identification of contact condition

 

5. Different hand handle color is to indicate the rated current

 

6. Wide rated current scope to serve as general switch at home service

 

 

Specitifcation:

 
Technology Specification & Electrical Specification
Electric standard IEC61009; GB 16917.0
Trip time Non-time delay; Minimal 10ms time delay
Rated voltage 230V; 50HZ          230V/400V
Rated surplus operating current 10; 30; 100; 300mA
Selection grade 3
Rated braking capacity 10kA
Rated current 6-40A
Tripping character B, C, D characteristic curve
Maximum connected fuse 100A gL(> 10kA)
Environment  capability According to the IEC 1008 standard
Case protection grade IP40 after installation
Electric life Not less than 4000 times of breaking and closing
Mechanical life Not less than 2000 times of breaking and closing
Mechanical Parameter
Installation mode Installation at the DIN guide rail of 35mm
Terminal block capacity Generatrix thickness 0.8-2mm
Shell width 35mm (1P+N)

 

 

The over-current tripping unit protection feature:

 

Sequence NO. Release Test current I/In Start state Tripping time Expected restlt
1 C 1.13In Cold state t≤1h Not tripping
2 C 1.45In Start right after the serial NO.1 test t<1h tripping
3 C 2.55In Cold state 1s<t<60s tripping
4 C 5In Cold state t≤0.1s Not tripping
5 C 10In Cold state t<0.1s tripping
 

 

 

Loading capacity:

 

1P+N 10kA Residual Circuit Breaker 2 Pole with Over Current RCBO 0

 

 

 

Our service:

 

1. Samples: provided freely

 

2. Package: packed in standard cartons, special packing is negotiable

 

3. Warranty: 2 years at least

 

4. Delivery: within 30days after received the deposit.

 

5. OEM, ODM is acceptable

 

6. We can help you with any of your idea to design and put it into production.

 

7. Provide help for building factories, such as: spare parts, technical questions, financial matter, management problem, approach of sales...

Contact Details
Zhejiang KRIPAL Electric Co., Ltd.

Contact Person: Allen

Send your inquiry directly to us
Best Products