Place of Origin: | China |
Brand Name: | KRIPAL |
Certification: | CE |
Model Number: | UKC1-9M |
Minimum Order Quantity: | 100pcs |
---|---|
Price: | negotiable |
Packaging Details: | Each unit packed in a individual box |
Delivery Time: | 20 days and depends on ordering quantity |
Payment Terms: | T/T, L/C |
Supply Ability: | 50000 pcs per month |
Brand: | KRIPAL | Current Range: | 6A 9A 12A 16A |
---|---|---|---|
Poles: | 3P | Auxiliary: | 1NO Or 1NC |
Contacts: | Silver | Coil: | AC |
High Light: | heat pump contactor,ac magnetic contactor |
Motor Protection Circuit Breaker AC Contactor Magnetic 24V 110V 220V 380V 1NO or 1NC
Description:
The power consumption of the UKC1- low consumption type contactor is 1.2W.
Low coil power consumption greatly expands application flexibility. Standard AC coils require 1.8 watts.
Directly drive contactor by transistor output of PLC
This contactor can be driven by a transistor output of a PLC or electronic equipment such as photoelectric switch, or a proximity limit switch. Therefore, it is possible for this contactor to directly interface without interface relay for driving a 3-phase induction motor.
AC Contactors (Magnetic Contactor) provide remote control of primarily electric motors and compensation & heating systems by cable. They protect the instruments and equipments against overload currents by using thermal relays, for capacitor switching contactor.
While switching on a capacitive circuit, a high frequency and large transient current peaks are produced. Switching of capacitor for a single or one of the capacitor banks are different from each other. Step by step "switching on" operation is more difficult for contactor than capacitor bank. Because during this operation for capacitor bank, compensated current occurs. For this reason selecting of suitable contactors the compensating current must be take into consideration for 50kVAR and above, and for less than 50kVAR can be omitted.
Specifications:
Rated current | AC3(IEC60947 | AC1 Ith | Aux. Contacts | Type | |||
220-240V | 380-440V | 550-550V | 690V | ||||
6A | 1.5KW 7A | 2.2KW 6A | 3KW 5A | 3KW 4A | 20A | 1NO or 1NC | UKC1-6M |
9A | 2.2KW 9A | 4KW 9A | 3.7KW 6A | 4KW 5A | 20A | 1NO or 2NC | UKC1-9M |
12A | 3KW 12A | 5.5KW 12A | 4KW 7A | 4KW 55A | 20A | 1NO or 3NC | UKC1-12M |
16A | 4KW 15A | 7.5KW 16A | 5.5KW 9A | 4KW 5A | 20A | 1NO or 4NC | UKC1-16M |
AC coil Voltage (50/60Hz): 24, 36, 42, 48, 110, 115, 120, 127, 220/208, 220, 220/230, 230/240, 256, 277, 380/440, 400, 440, 480, 500, 550 | |||||||
Characteristics(440VAC) | |||||||
Rated current | 6A | 9A | 12A | 18A | |||
Short circuit current(max) | 380V | 60 | 90 | 120 | 160 | ||
660V | 72 | 108 | 144 | 180 | |||
Breaking current(max) | 380V | 48 | 72 | 96 | 128 | ||
660V | 60 | 90 | 120 | 150 | |||
Operation cycles per hour | AC-3 | 1800 | 1800 | 1800 | 1800 | ||
AC-4 | 300 | 300 | 300 | 300 | |||
electrical life time (10, 000 times) | AC-3 | 100 | 100 | 100 | 100 | ||
AC-4 | 20 | 20 | 20 | 20 | |||
Machanical Life time(1000 times) | 1200 | 1200 | 1200 | 1200 | |||
Aux contacts | Standard configuration | 1NO | 1NO | 1NO | 1NO | ||
Top mointing | AU-2M/4M | AU-2M/4M | AU-2M/4M | AU-2M/4M | |||
Panel Installation | guid screw | guid screw | guid screw | guid screw | |||
Characteristices of the coil | |||||||
Coil voltage | AC | ||||||
coil consumption(VA) | 2 | ||||||
Pick-ip | 32va | ||||||
Maintain | 6va | ||||||
Selections of pick-up voltage(%) | 80-110 | ||||||
Selections of droup-out voltage(%) | 30-40 | ||||||
Pick-up times | 10-20 | ||||||
droup-out times | 35-45 |
Coil voltage(AC 50/60HZ):
24V,36V, 42V, 48V, 110V, 115V, 120V, 200V/208V, 220V, 220V/230V,230V/240V, 256V, 277V, 380V/400V, 400V,440V, 480V, 500V, 550V
Benefits for mini AC contactors:
Low consumption power
Saving panel size
Installation space is reduced to 50% of conventional DC operated contactors achieving high performance.
Main application fields for DC mini contactors:
Lighting for out-door
Car washing facilities
Crain hoist
Lighting of sports facilities
Pump
Compressor
Vending machine
Painting machine
Show case
It is possible to expand the control wire length since voltage drop in wires is small.
Normal working conditions and installation conditions
1. Surrounding air environment is from -5 degrees Celsius to +50 degrees
2. Altitude does not exceed 2000m.
3. The tilt with the vertical is not more than 5 degrees.
4. The pollution degree of installation sites is level 3.
5. Installation category is class II.
6. No space of significant shake and shock and vibration.
Contact Person: Allen
IP66 IP67 32 Amp Rotary Isolator Switch Disconnector For Solar PV System
Weatherproof 100 Amp Disconnect Switch with 1NO+1NC For Rotary Isolating
Waterproof IP65 Rotary Isolator Switch / 2 Pole 3 Pole Disconnect Switch
Blue IP44 Industrial Power Socket Pin And Sleeve Electrical Connectors
Pin and Sleeve Plug Industrial Power Socket IP44 IP67 Coupler Connector
Mechanical Interlock Industrial Power Switched Sockets , Single / Three Phase
Three Phase Fire-retardant Enclsoure AC Compressor Contactor And Relays 180A
Electrical Switch Over Switch AC Contactor Magnetic 9A 12A 18A 22A
GMC 4P Mini Mechanical Interlocking Home AC Contactor Gmc 9mr 9A 3 Phase Contactor
9A 12A 18A 22A Single Phase DOL Starter AC Contactor Definite Purpose