UKM30-400S 400A 4P Molded Case Circuit Breaker , Mccb Circuit Breaker Economic

UKM30-400S 400A 4P Molded Case Circuit Breaker , Mccb Circuit Breaker Economic

  • UKM30-400S 400A 4P Molded Case Circuit Breaker , Mccb Circuit Breaker Economic
UKM30-400S 400A 4P Molded Case Circuit Breaker , Mccb Circuit Breaker Economic
Product Details:
Place of Origin: China
Brand Name: KRIPAL
Certification: CE, CCC
Model Number: UKM30-400S 400A 4P
Payment & Shipping Terms:
Minimum Order Quantity: 500 pcs
Price: negotiable
Packaging Details: Each unit packed in a individual box 2PCS/ CTN Carton size: 51*33*21.5 CM
Delivery Time: 20 days and depends on ordering quantity
Payment Terms: T/T, L/C
Supply Ability: 30000 pcs per month
Contact Now
Detailed Product Description
Ampere Range: 400A Poles Available: 4 P
Purpose: Protect Power Distribution Breaking Capacity: 70/70KA
High Light:

Earth Leakage Circuit Breaker

,

Residential Circuit Breakers

 

Molded Case Circuit Breaker UKM30-400S 400A 4P Rated current range:400A,350A,300A,250A economic

 

MCCB

 

It is a mechanical switching device that can connect, load and break the current under the normal circuit and can connect, load and break the current within a period of time under the unnormal circuit.

 

General

 

Advanced design,reliable performance,high technical guid line;elegant appearance, small bulk. It adopts micro-electronic technology, and has intelligent control function; complete series are zero arcintg.

 

Application

 

The MCCB is applied in the distribution network circuit of AC50Hz, with rated voltage up to 690V, rated current up to 800A. It is used to protect circuits and power-supply equipments from damage of overload, under-voltage,short-circuit,etc, can also be used for infrequent starting of motor and provide overload, short circuit and under-voltage protection for the motor. Exact and facility setting up of the protection characteristics for electronic type release and intelligence type release. The intelligent type release has serial comunication interface, can comply with the request of communication.

 

The MCCBs are meet requirement of IEC / EN 60947-2.

 

 

Technical data:

 

Parameter name Value
UKM30-400S
Rated current In(A) 250,300,350,400
Number of poles 4
Rated voltage Ui(V) AC690
Arc distance (mm) ≤50(0)*
Overcurrent release Combined: thermal &electromagnetic
Rated ultimate breaking capitily Icu/Ics(KA) AC690V 10/10
AC400V 70/70
AC230V 100/100
Operational performance (times) ON 1000
OFF 4000
Dimensions (mm) a 185
b 257
c 103


*"0"arcing distance: please specify when ordering if you require.

 

UKM30-400S 400A 4P Molded Case Circuit Breaker , Mccb Circuit Breaker Economic 0

 

 

Normal working condition

 

The MCCB applies to the following working conddition

A. Ambient air temperature ≤+40℃ and >-5

B. Altitude ≤ 2000m

C. Air relative humidity is under 50% at +40℃, it permits upper relative humidity at lower temperature, the most humid month's lowest temperature does not exceed +25℃, the month's average relative humidity does not exceed 90%.

D. Class of pollution:class 3. There are no gas and electric conduction dust which may explode, dipping and broken insulation.

E. Installation type: 

F. The "1,3,5,N1" terminals connect with power supply, the "2,4,6,N2" terminals connect with load, can not mixed.

G. The MCCB's installing surface should upright with level, upright installing , the power supply terminal should at upside , load terminal should at underside, it also can be landscape orientation installing.

 

UKM30-400S 400A 4P Molded Case Circuit Breaker , Mccb Circuit Breaker Economic 1

 

The product shall be operated under the following environmental conditions:

 

● Non-explosive;

● Does not contain corrosive gases and vapors in concentrations destroying metals and insulation;

● Not rich conductive dust and vapors;

● Lack of direct exposure to ultraviolet radiation;

● Should not be signifinant shock or vibration.

 

Transport ans storage are only permitted in the original packing.

 

The ambient storage temperature:-45...+60° C and humidity not above80% (at 25° C without condensation).

 

 

Installation and operating

 

The electrical work shall be performed by qualified personnel.

 

 

Before performing wiring work, turn off the upstream circuit breaker and ensure that no curren is flowing through the breaker to be wired.

 

Failure to do so may expose you to shock hazard.

 

When connecting any wire ,tighten the terminal screw to the torque specified in this manual. Failure to do so may cause a fire.

                                        

Do not install the breaker in an abnormal environment. Protect the circuit breaker so that the foreign particles,such as dust,concrete or/and iron power, water and other moistures will not enter the breaker. Failture to do so may make the breaker inoperative. Connect the circuit breaker to power supply appropriate to the rating voltage. Failure to do so may make the breaker inoperative or damage it. The breaker is installed in a plastic or metal box on a mounting plate with latches having two fixed positions. Power can be supplied from both the upper and lower contacrts.Terminals allow to connect copper or aluminum conductors.Before connecting standed conductors, they must be tipped using an appropriate tool.

Contact Details
Zhejiang KRIPAL Electric Co., Ltd.

Contact Person: Daisy

Tel: +8615706751663

Send your inquiry directly to us
Best Products
Other Products