Place of Origin: | China |
Brand Name: | KRIPAL |
Certification: | CE,CCC |
Model Number: | UKM30-63S |
Minimum Order Quantity: | 500 pcs |
---|---|
Price: | negotiable |
Packaging Details: | Each unit packed in a individual box 30PCS per carton :44*29*32CM |
Delivery Time: | 20 days and depends on ordering quantity |
Payment Terms: | T/T, L/C |
Supply Ability: | 30000 pcs per month |
Ampere Range: | 10~60A | Poles Available: | 3P |
---|---|---|---|
Trip Unit: | Thermal Magnetic | Warranty: | 18 Months |
High Light: | Earth Leakage Circuit Breaker,Residential Circuit Breakers |
UKM30-63S 50A 3P Magnetic Type Molded Case Circuit Breaker AC600V Rated current range10~63A Arcing distance:≤50
Brief Introduction
UKM30 series moulded case circuit breaker (circuit breaker for short) is high-tech products in 21st century with advanced design,high performance,pleasant appearance and delicate dimension. Meanwhile, they are intelligent controlled and developed with microelectronic technology.
Usage & Appliance
The circuit breaker is used in the electrical system of AC 50Hz,related voltage of up to 690V, rated current of up to 800A to prevent the system from overload,short-circuit and under-voltage and to control the infrequent operation of motor.
Weight: 0.75KG
Rated operation frequency (per hour): 120
Standards
It is complied with GB1408.2 and IEC60947-2 section 2 and etc.
Normal operation condition
The circuit breaker could be used in the following working conditions:
A. Ambient air temperature not higher than +40 ℃ and not lower than -5 ℃.
B. Altitude no more than 2000m
C. The relative air humidity is not more than 50% in the max at the temperature of +40 ℃. The higher relative humidity is allowable at the lower temperature. The lowest monthly average temperature not higher than 25 ℃ in the most moist month and the max relative humidity should be no more than 90%.
D. Pollution degree:Grade 3. Three is no explosion factor, corrosive metal and the gas destroying the insulation and the electric dust.
E. Installation type:Ⅲ
F. The terminals of 1,3,5,N1 should be connected with the power supply and the terminals of 2,4,6,N2 should be connected with the load. Reverse wiring is forbidden.
UKM30-63S 50A 3P Magnetic Type Molded Case Circuit Breaker AC600V Rated current range10~63A Arcing distance:≤50
Order No.
Model | Current (A) | Poles (P) |
UKM30-63S 10A 3P | 10 | 3 |
UKM30-63S 16A 3P | 16 | 3 |
UKM30-63S 20A 3P | 20 | 3 |
UKM30-63S 32A 3P | 32 | 3 |
UKM30-63S 40A 3P | 40 | 3 |
UKM30-63S 50A 3P | 50 | 3 |
UKM30-63S 63A 3P | 63 | 3 |
Main technical parameter
Rated current (A) | 10,16,20,32,40,50,63 | |
Poles (P) | 3 | |
Rated insulation voltage Ui (V) | AC600 | |
Arcing distance(mm) | ≤50(0*) | |
Rated ultimate / service short-circuit breaking capacity (KA) | AC690V | - |
AC400V | 10/5 | |
AC230V | 25/13 | |
Operational performance (times) | ON | 6000 |
OFF | 8500 | |
Weight (kg) | 0.75 | |
Rated operation frequency (per hour) | 120 |
*0 arcing distance: please specify when ordering if you require.
UKM30-63S 50A 3P Magnetic Type Molded Case Circuit Breaker AC600V Rated current range10~63A Arcing distance:≤50
Contact Person: Daisy
Tel: +8615706751663
IP66 IP67 32 Amp Rotary Isolator Switch Disconnector For Solar PV System
Weatherproof 100 Amp Disconnect Switch with 1NO+1NC For Rotary Isolating
Waterproof IP65 Rotary Isolator Switch / 2 Pole 3 Pole Disconnect Switch
Blue IP44 Industrial Power Socket Pin And Sleeve Electrical Connectors
Pin and Sleeve Plug Industrial Power Socket IP44 IP67 Coupler Connector
Mechanical Interlock Industrial Power Switched Sockets , Single / Three Phase
Three Phase Fire-retardant Enclsoure AC Compressor Contactor And Relays 180A
Electrical Switch Over Switch AC Contactor Magnetic 9A 12A 18A 22A
GMC 4P Mini Mechanical Interlocking Home AC Contactor Gmc 9mr 9A 3 Phase Contactor
9A 12A 18A 22A Single Phase DOL Starter AC Contactor Definite Purpose