Send Message
Home ProductsMolded Case Circuit Breaker

2P / 3P Standard Magnetic Type Molded Case Circuit Breaker AC600V 10A 16A 20A 32A 40A 50A 63A

2P / 3P Standard Magnetic Type Molded Case Circuit Breaker AC600V 10A 16A 20A 32A 40A 50A 63A

  • 2P / 3P Standard Magnetic Type Molded Case Circuit Breaker AC600V 10A 16A 20A 32A 40A 50A 63A
2P / 3P Standard Magnetic Type Molded Case Circuit Breaker AC600V 10A 16A 20A 32A 40A 50A 63A
Product Details:
Place of Origin: China
Brand Name: KRIPAL
Certification: CE
Model Number: UKM30-63S
Payment & Shipping Terms:
Minimum Order Quantity: 500 pcs
Price: negotiable
Packaging Details: Each unit packed in a individual box
Delivery Time: 20 days and depends on ordering quantity
Payment Terms: T/T, L/C
Supply Ability: 30000 pcs per month
Contact Now
Detailed Product Description
Ampere Range: 10A 16A 20A 32A 40A 50A 63A Poles Available: 2P 3P
Certificate: CE Trip Unit: Thermal Magnetic
Warranty: 2 Years
Highlight:

Earth Leakage Circuit Breaker

,

Residential Circuit Breakers

 

2P / 3P Standard Magnetic Type Molded Case Circuit Breaker AC600V 10A 16A 20A 32A 40A 50A 63A

 

UKM30-63S 2P/3P Standard Magnetic Type Molded Case Circuit Breaker AC600V 10A 16A 20A 32A 40A 50A 63A

 

 


 2P / 3P Standard Magnetic Type Molded Case Circuit Breaker AC600V 10A 16A 20A 32A 40A 50A 63A 0

 

 

 

Brief Introduction

 

UKM30 series moulded case circuit breaker (circuit breaker for short) is high-tech products in 21st century with advanced design,high performance,pleasant appearance and delicate dimension. Meanwhile, they are intelligent controlled and developed with microelectronic technology.

 

 

Usage & Appliance

 

The circuit breaker is used in the electrical system of AC 50Hz,related voltage of up to 690V, rated current of up to 800A to prevent the system from overload,short-circuit and under-voltage and to control the infrequent operation of motor.

 

 

Standards

 

It is complied with GB1408.2 and IEC60947-2 section 2 and etc.

 

 

Normal operation condition

 

The circuit breaker could be used in the following working conditions:

A. Ambient air temperature not higher than +40 ℃ and not lower than -5 ℃.

B. Altitude no more than 2000m

C. The relative air humidity is not more than 50% in the max at the temperature of +40 ℃. The higher relative humidity is allowable at the lower temperature. The lowest monthly average temperature not higher than 25 ℃ in the most moist month and the max relative humidity should be no more than 90%.

D. Pollution degree:Grade 3. Three is no explosion factor, corrosive metal and the gas destroying the insulation and the electric dust.

E. Installation type:Ⅲ

F. The terminals of 1,3,5,N1 should be connected with the power supply and the terminals of 2,4,6,N2 should be connected with the load. Reverse wiring is forbidden.

 

 

Low-voltage power distribution network

 

2P / 3P Standard Magnetic Type Molded Case Circuit Breaker AC600V 10A 16A 20A 32A 40A 50A 63A 1

 

 

Control and protection of motor 

 

2P / 3P Standard Magnetic Type Molded Case Circuit Breaker AC600V 10A 16A 20A 32A 40A 50A 63A 2

 

Dual power changeover system

 

2P / 3P Standard Magnetic Type Molded Case Circuit Breaker AC600V 10A 16A 20A 32A 40A 50A 63A 3

 

UKM30-63S 2P/3P Standard Magnetic Type Molded Case Circuit Breaker AC600V 10A 16A 20A 32A 40A 50A 63A

 

 

 

Order No.

 

Model Current (A) Poles (P)
UKM30-63S 10A 2P 10 2
UKM30-63S 16A 2P 16 2
UKM30-63S 20A 2P 20 2
UKM30-63S 32A 2P 32 2
UKM30-63S 40A 2P 40 2
UKM30-63S 50A 2P 50 2
UKM30-63S 63A 2P 63 2
UKM30-63S 10A 3P 10 3
UKM30-63S 16A 3P 16 3
UKM30-63S 20A 3P 20 3
UKM30-63S 32A 3P 32 3
UKM30-63S 40A 3P 40 3
UKM30-63S 50A 3P 50 3
UKM30-63S 63A 3P 63 3

 

 

 

Main technical parameter

 

Rated current (A) 10,16,20,32,40,50,63
Poles (P) 2,3
Rated insulation voltage Ui (V) AC600
Arcing distance(mm) ≤50(0*)
Rated ultimate / service short-circuit breaking capacity (KA) AC690V -
AC400V 10/5
AC230V 25/13
Operational performance (times) ON 6000
OFF 8500
Weight (kg) 0.75
Rated operation frequency (per hour) 120

*0 arcing distance: please specify when ordering if you require.

 

 

 

Dimension (mm)

 

2P / 3P Standard Magnetic Type Molded Case Circuit Breaker AC600V 10A 16A 20A 32A 40A 50A 63A 4

 

 

a 75
b 130
c 68

 

 

 

UKM30-63S 2P/3P Standard Magnetic Type Molded Case Circuit Breaker AC600V 10A 16A 20A 32A 40A 50A 63A

Contact Details
Zhejiang KRIPAL Electric Co., Ltd.

Contact Person: Allen

Send your inquiry directly to us