Found 32 Products For "
heat pump contactor
"
High End AC motor 3 Phase Capacitor Switching Contactor 32A 40A
High End AC motor 3 Phase Capacitor Switching Contactor 32A 40A Description: UKC1 series swithing capacitor contactor (hereafter called " the contactor " for short ) are the contactors specially used for make and break of low voltage shunt capacitors and widely used in reactive power used for make and break of capacitor up to 60kvar in electric power system of AC 50Hz and rated working voltage 380V for the purpose of improvement of power factor. We have 9A, 12A, 18A, 22A, 32A
Auxiliary Contactor Delay On Make or DelayTimer for AC/DC contactor 1NO 1NC
Auxiliary Contactor Delay On Make or DelayTimer for AC/DC contactor 1NO 1NC UT series auxiliary contact blocks are installed on the top of UKC1 series AC contactor for expanding the couples of auxiliary contacts points. IEC utilization categories The current rating of the AC/DC contactor depends on utilization category. Example IEC categories in standard 60947 are described as: AC-1 - Non-inductive or slightly inductive loads, resistance furnaces AC-2 - Starting of slip-ring
Electrical 3P 600V AC Contactor Motor Protection / Mechanical Interlocking Contactor
Electrical 600V AC Contactor Motor Protection / Mechanical Interlocking Contactor Description: MC(LS) series AC contactor is suitable for using in the circuits up to the rated voltage 660VAC 50Hz or 60Hz, rated current 9A to 85A, making and breaking and frequent starting, controls the AC motor. Combined with the auxiliary contact group, air delayer, machine interlocking device etc, it is combined into the delay contactor, mechanical interlocking contactor, drat-delta starter,
Electrical Switch Over Switch AC Contactor Magnetic 9A 12A 18A 22A
Electrical Switch Over Switch AC Contactor Magnetic 9A 12A 18A 22A Description: UKC1-...C switching capacitor can be used for it's own only of on-off low voltage shuntwound capacitor.It used widely for no power and power equalize equipment of auto equalize.It can be fit electrical system of AC frequency 50 Hz,rated voltage is below 380v, on-off capacitor is below 90kvar,improved to power factor. The CJ19C type switching capacitor contactor is our factory improved to design
Anti-Electric 32A/40A AC/DC Contactor 220V UKC1 Series Into Electromagnetic Starter
Anti-Electric 32A/40A AC/DC Contactor 220V UKC1 Series Into Electromagnetic Starter Description: UKC1 series AC Contactor is suitable for using in the circuits up to the rated voltage 660V AC50Hz or 60Hz, rated current up to 630A, for making, breaking, frequently starting & controlling the AC motor. Combined with the auxiliary contact block, timer delay & machine interlocking device etc, it becomes the delay contactor, mechanical interlocking contactor, star-delta starter.
9A 12A 18A 22A Single Phase DOL Starter AC Contactor Definite Purpose
9A 12A 18A 22A Single Phase DOL Starter AC Contactor Definite Purpose A magnetic starter is a device designed to provide power to electric motors. It includes a contactor as an essential component, while also providing power-cutoff, under-voltage, and overload protection. Description: UKW1 series magnetic motor starter are suitable for 50Hz or 60Hz, rated voltage up to 660V, current up to 95A circuit. In order to protect motor starting, accelerating the motor to rated rev,
Motor Starter Circuit Breaker MPCB GV2-M GV2-ME GV2-RS GV3-M GV3-ME
Motor Starter Circuit Breaker MPCB GV2-M GV2-ME GV2-RS GV3-M GV3-ME Description: MPCB are designed for connecion by screw clamp terminals. It can be supplied with lugs or spring terminal connections. Resistant to harsh environment, vibration and impact and are even more effective when conductors without cable ends are used. Each connection can take two independent conductors. Operation: Control is manual and local when the motor circuit-breaker is used on its own. Control is
GMC AC/DC Mini Contactor Motor Protection Switch Low consumption 6A,9A,12A,16A
GMC AC/DC Mini Contactor Motor Protection Switch Low consumption 6A,9A,12A,16A AC Contactors (Magnetic Contactor) provide remote control of primarily electric motors and compensation & heating systems by cable. They protect the instruments and equipments against overload currents by using thermal relays, for capacitor switching contactor. While switching on a capacitive circuit, a high frequency and large transient current peaks are produced. Switching of capacitor for a
32A 3 Pole 230-440V IP65 Waterproof Isolator Switch IEC standard
32A 3 Pole 230-440V IP65 Waterproof Isolator Switch IEC standard The switch is a shell made of glass fiber reinforced unsaturated polyester resin: the spring energy storage acceleration mechanism can quickly realize the connection and disconnection. The contact structure is a parallel double break point and two separate contact surfaces, and the contact is guaranteed by a leaf spring. Head pressure; the switch can automatically determine the limit position of on-off, and has